Maxim > 方案 > 传输节点、接入节点、上/下路复用器和数字交叉连接
热插拔
|
|
| 显示 |
标题/型号 |
关键优势 |
| QV PDF |
低电压、三路、热插拔控制器/供电排序器/电压跟踪器 MAX5930A, MAX5931A, MAX5931B

| 三通道热插拔控制器,提供排序、跟踪或独立的通/断控制,支持低压电源 |
| QV PDF |
低电压、四路、热插拔控制器/电源排序器 MAX5927A, MAX5929A, MAX5929B, MAX5929C, MAX5929D

| 三/四通道热插拔控制器,为低压电源提供排序、跟踪或独立的通/断控制 |
| QV PDF |
+48V、四路、热插拔控制器,用于LAN供电 MAX5913A, MAX5914A

| 高度集成的方案,可有效减小电路板尺寸、降低成本、缩短系统设计时间 |
| QV PDF |
-48V热插拔控制器,可避免VIN阶跃故障,无需RSENSE MAX5936, MAX5937

| 热插拔控制器,可避免VIN阶跃故障,无需RSENSE,用于-10V至-80V电源 |
| QV PDF |
正电源、高压、热插拔控制器,提供可选择的故障管理和状态极性 MAX5934, MAX5934A

| |
| QV PDF |
低电压、四路、热插拔控制器/供电排序器 MAX5927, MAX5929

| 三/四通道热插拔控制器,为低压电源提供排序、跟踪或独立的通/断控制 |
| QV PDF |
低电压、双路、热插拔控制器/供电排序器 MAX5904, MAX5905, MAX5906, MAX5907, MAX5908, MAX5909

| |
| QV PDF |
+65V、Simple Swapper热插拔开关 MAX5910, MAX5917

| |
| QV PDF |
-100V、SOT23/TDFN封装、Simple Swapper热插拔控制器 MAX5900, MAX5901

| |
| QV PDF |
+72V、SOT23/TDFN封装、Simple Swapper热插拔控制器 MAX5902, MAX5903

| |
| QV PDF |
-48V、Simple Swapper热插拔开关 MAX5911, MAX5912

| -48V热插拔开关,适用于IP电话和通过同一电缆传输数据、电源的数据终端设备 |
| QV PDF |
3V至12V、限流型、热插拔控制器,带有自动重试以及DualSpeed/BiLevel故障保护 MAX4271, MAX4272, MAX4273

| 3V至12V热插拔控制器,提供闭锁保护或自动重试功能,8引脚SO封装 |
| Key Specifications: Hot Swap Controllers |
| Part Number |
VIN (V) |
VIN (V) |
Low Volt. |
High Volt. |
Voltage Polarity |
Type |
Fault Condition Control |
Channels |
Features |
Package/Pins |
| min |
max |
| MAX5934 |
9 |
80 |
No |
Yes |
Positive |
Positive, High-Voltage |
Programmable Latched Off or Periodic Retry |
1 |
| 3 Power-Good Outputs for Output U/V, Input O/V, & Gate Voltage Status | | Adjustable Auto-Retry Duty Cycle and Circuit-Breaker Timeout | | Latch or Auto-Restart Fault Management | | Output Undervoltage Monitor | | Power-Good Output Programmable |
|
|
| MAX5927 |
1 |
13.2 |
Yes |
No |
Positive |
Positive, Low-Voltage |
Programmable Latched Off or Periodic Retry |
4 |
| 25mV Circuit Breaker Threshold | | 50mA Gate Pull Down Current During Short Circuit Protection | | Adjustable Auto-Retry Duty Cycle and Over-Current Timeout | | Configurable Tracking, Sequencing, or Independent Operation Modes | | Independent ON/OFF Control for Each Channel |
|
|
| MAX5929 |
1 |
13.2 |
Yes |
No |
Positive |
Positive, Low-Voltage |
| Latched Off | | Periodic Retry |
|
4 |
| 25mV Circuit Breaker Threshold | | 50mA Gate Pull Down Current During Short Circuit Protection | | Auto-Retry Fault Management | | Configurable Tracking, Sequencing, or Independent Operation Modes | | Fault Status Output | | In-Rush Current and Short Circuit Protection | | Independent ON/OFF Control for Each Channel | | Latch or Auto-Restart Fault Management | | Power-Good Output (Active-High) | | Power-Good Output (Active-Low) |
|
|
| MAX5904 |
1 |
13.2 |
Yes |
No |
Positive |
Positive, Low-Voltage |
Periodic Retry |
2 |
| 25mV Circuit Breaker Threshold | | On/Off Control | | Regulated In-Rush Current | | Short-Circuit Protection | | VariableSpeed/BiLevel Protection |
|
|
| MAX5905 |
1 |
13.2 |
Yes |
No |
Positive |
Positive, Low-Voltage |
Latched Off |
2 |
| 25mV Circuit Breaker Threshold | | On/Off Control | | Regulated In-Rush Current | | Short-Circuit Protection | | VariableSpeed/BiLevel Protection |
|
|
| MAX5906 |
1 |
13.2 |
Yes |
No |
Positive |
Positive, Low-Voltage |
Periodic Retry |
2 |
| Adjustable Circuit Breaker Threshold | | Output Undervoltage/Overvoltage Protection | | Regulated In-Rush Current | | Short-Circuit Protection | | VariableSpeed/BiLevel Protection |
|
|
| MAX5907 |
1 |
13.2 |
Yes |
No |
Positive |
Positive, Low-Voltage |
Latched Off |
2 |
| Adjustable Circuit Breaker Threshold | | Output Undervoltage/Overvoltage Protection | | Regulated In-Rush Current | | Short-Circuit Protection | | VariableSpeed/BiLevel Protection |
|
|
| MAX5908 |
1 |
13.2 |
Yes |
No |
Positive |
Positive, Low-Voltage |
Periodic Retry |
2 |
| Adjustable Circuit Breaker Threshold | | Output Undervoltage/Overvoltage Protection | | Regulated In-Rush Current | | Short-Circuit Protection | | VariableSpeed/BiLevel Protection |
|
|
| MAX5909 |
1 |
13.2 |
Yes |
No |
Positive |
Positive, Low-Voltage |
Latched Off |
2 |
| Adjustable Circuit Breaker Threshold | | Output Undervoltage/Overvoltage Protection | | Regulated In-Rush Current | | Short-Circuit Protection | | VariableSpeed/BiLevel Protection |
|
|
| MAX5910 |
10 |
65 |
No |
Yes |
Positive |
Positive, High-Voltage |
Latched Off |
1 |
| Fault Status Output | | Internal Switch Protection | | On/Off Control | | Open-Circuit Detection | | Regulated In-Rush Current | | Short-Circuit Protection | | Thermal Shutdown |
|
|
| MAX5917 |
10 |
65 |
No |
Yes |
Positive |
Positive, High-Voltage |
Latched Off |
1 |
| Fault Status Output | | Internal Switch Protection | | On/Off Control | | Open-Circuit Detection | | Regulated DualSpeed/BiLevel Current Limit | | Regulated In-Rush Current | | Short-Circuit Protection | | Thermal Shutdown |
|
|
| MAX5900 |
-9 |
-100 |
No |
Yes |
Negative |
Negative, High-Voltage |
| Latched Off | | Periodic Retry |
|
1 |
| Auto-Retry Fault Management | | Circuit-Breaker Function | | Latch or Auto-Restart Fault Management | | On/Off Control | | Power-Good Output (Active-Low) | | Regulated In-Rush Current | | Short-Circuit Protection | | Thermal Shutdown |
|
|
| MAX5901 |
-9 |
-100 |
No |
Yes |
Negative |
Negative, High-Voltage |
| Latched Off | | Periodic Retry |
|
1 |
| Auto-Retry Fault Management | | Circuit-Breaker Function | | Latch or Auto-Restart Fault Management | | On/Off Control | | Power-Good Output (Active-High) | | Regulated In-Rush Current | | Short-Circuit Protection | | Thermal Shutdown |
|
|
| MAX5911 |
-16 |
-65 |
No |
Yes |
Negative |
Negative, High-Voltage |
Latched Off |
1 |
| Fault Status Output | | Internal Switch Protection | | On/Off Control | | Open-Circuit Detection | | Regulated In-Rush Current | | Short-Circuit Protection | | Thermal Shutdown |
|
|
| MAX5912 |
-16 |
-65 |
No |
Yes |
Negative |
Negative, High-Voltage |
Latched Off |
1 |
| Fault Status Output | | Internal Switch Protection | | On/Off Control | | Open-Circuit Detection | | Regulated In-Rush Current | | Short-Circuit Protection | | Thermal Shutdown |
|
|
| MAX5902 |
9 |
72 |
No |
Yes |
Positive |
Positive, High-Voltage |
| Latched Off | | Latched Off or Periodic Retry | | Periodic Retry | | Programmable Latched Off or Periodic Retry |
|
1 |
| Circuit-Breaker Function | | On/Off Control | | Power-Good Output (Active-Low) | | Regulated In-Rush Current | | Short-Circuit Protection | | Thermal Shutdown |
|
|
| MAX5903 |
9 |
72 |
No |
Yes |
Positive |
Positive, High-Voltage |
| Latched Off | | Latched Off or Periodic Retry | | Periodic Retry | | Programmable Latched Off or Periodic Retry |
|
1 |
| Circuit-Breaker Function | | On/Off Control | | Power-Good Output (Active-Low) | | Regulated In-Rush Current | | Short-Circuit Protection | | Thermal Shutdown |
|
|
| MAX4271 |
2.7 |
13.2 |
Yes |
No |
Positive |
Positive, Low-Voltage |
Latched Off |
1 |
| On/Off and STAT Control | | Regulated DualSpeed/BiLevel Current Limit | | Short-Circuit Protection |
|
|
| MAX4272 |
2.7 |
13.2 |
Yes |
No |
Positive |
Positive, Low-Voltage |
Periodic Retry |
1 |
| On/Off and STAT Control | | Regulated DualSpeed/BiLevel Current Limit | | Short-Circuit Protection |
|
|
| MAX4273 |
2.7 |
13.2 |
Yes |
No |
Positive |
Positive, Low-Voltage |
Programmable Latched Off or Periodic Retry |
1 |
| On/Off, STAT, and POR Controls | | Regulated DualSpeed/BiLevel Current Limit | | Short-Circuit Protection |
|
|
|
See All Hot Swap Controllers (47)
|
|